{"product_id":"xy-j02-time-delay-relay-timer-module-6-30v-999-minute-cycle","title":"XY-J02 Time Delay Relay Timer Module 6-30V | 999 Min Cycle","description":"\n\u003ch2\u003eXY-J02 Single-Channel Time Delay Relay Timer Module\u003c\/h2\u003e\n\u003cp\u003eTake precise control of your automated circuits with the \u003cstrong\u003eXY-J02 1-Channel Time Delay Relay Module\u003c\/strong\u003e. Engineered for makers, hobbyists, and industrial users alike, this compact timer module delivers a wide operating voltage range (6–30V), flexible timing from 0.1 seconds up to 999 minutes, and multiple programmable operating modes — all in a rugged, industrial-grade package. Made in Mainland China.\u003c\/p\u003e\n\n\u003ch3\u003eKey Highlights\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWide Voltage Input:\u003c\/strong\u003e Operates on 6–30V DC and also supports 5.0V via Micro USB — extremely versatile for any project.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFlexible Timing Range:\u003c\/strong\u003e Continuously adjustable from 0.1 second (minimum) to 999 minutes (maximum) via three selectable decimal-point positions.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003e7 Operating Modes (P1.1 through P-4):\u003c\/strong\u003e Triggered delay ON, re-trigger, reset-on-trigger, delayed start, loop cycling, auto-cycle on power-up, and signal-hold modes.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOptocoupler Isolation:\u003c\/strong\u003e Enhanced anti-interference capability for reliable operation in noisy electrical environments.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEmergency STOP Key:\u003c\/strong\u003e Instantly halts timing and relay output at any moment; also used to select the decimal-point (timing range) position.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eReverse-Connection Protection:\u003c\/strong\u003e Accidentally wiring power backwards will not damage the module.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNon-Volatile Memory:\u003c\/strong\u003e All set parameters (OP on-time, CL off-time, LOP cycle count) are automatically saved after power loss and restored on the next power-up.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIndustrial-Grade PCB:\u003c\/strong\u003e Rated for operating temperatures from −40°C to +85°C; service life exceeding 100,000 relay operations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWorking Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6–30V DC (also supports 5V via Micro USB)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrigger Signal\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHigh-level trigger: 3.0V–24V (isolated or common ground selectable)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDC 30V \/ 5A or AC 220V \/ 5A\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eQuiescent Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20mA\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWorking Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50mA\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTiming Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1 second – 999 minutes (continuously adjustable)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e−40°C to +85°C\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e62 × 38 × 17 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eService Life\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;100,000 operations\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMade in Mainland China\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eOperating Modes Explained\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eP1.1:\u003c\/strong\u003e Trigger → relay ON for OP time → OFF. Re-trigger during OP is ignored.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eP1.2:\u003c\/strong\u003e Trigger → relay ON for OP time → OFF. Re-trigger restarts the OP countdown.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eP1.3:\u003c\/strong\u003e Trigger → relay ON for OP time → OFF. Re-trigger immediately disconnects relay and stops timing.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eP-2:\u003c\/strong\u003e Trigger → delay CL time → relay ON for OP time → relay OFF.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eP3.1:\u003c\/strong\u003e Trigger → relay ON (OP) → relay OFF (CL) → cycles; another trigger stops the cycle. Cycle count (LOP) is settable.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eP3.2:\u003c\/strong\u003e No trigger needed — auto-starts cycling relay ON (OP) \/ OFF (CL) at power-up. LOP settable.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eP-4:\u003c\/strong\u003e Signal-hold mode — relay stays ON as long as trigger is present; turns OFF after OP time elapses once signal is removed.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eHow to Set Parameters\u003c\/h3\u003e\n\u003col\u003e\n  \u003cli\u003ePower on the module; it will briefly flash the current mode (default P1.1), then show the main interface (\"000\").\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLong-press SET (2 sec)\u003c\/strong\u003e to enter Mode Selection. Use UP\/DOWN buttons to scroll through P1.1 → P-4.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eShort-press SET\u003c\/strong\u003e to begin setting parameters (OP, CL, LOP). Adjust values with UP\/DOWN (short press = ±1 unit; long press = rapid change).\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eShort-press STOP\u003c\/strong\u003e to shift the decimal point and select the timing range (seconds, tenths of seconds, or minutes).\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLong-press SET (2 sec)\u003c\/strong\u003e to save all settings and return to the main interface.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003e\u003cem\u003eTip: At any time on the main interface, short-press SET to review all parameters for the currently active mode.\u003c\/em\u003e\u003c\/p\u003e\n\n\u003ch3\u003eImportant Note on Relay Output\u003c\/h3\u003e\n\u003cp\u003eThe relay output is a \u003cstrong\u003epassive dry contact\u003c\/strong\u003e — it provides NO voltage of its own. It simply opens or closes a circuit path. Connect your load's power supply through the relay's COM\/NO\/NC terminals to switch your device on and off.\u003c\/p\u003e\n\n\u003cp\u003eLearn more: \u003ca href=\"https:\/\/www.osha.gov\/personal-protective-equipment\" target=\"_blank\" rel=\"noopener\"\u003eOSHA on personal protective equipment\u003c\/a\u003e\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003ch4\u003eQ: What power supply does the XY-J02 relay timer module require?\u003c\/h4\u003e\n\u003cp\u003eA: The XY-J02 relay timer module supports a wide input voltage of 6–30V DC. It also conveniently accepts 5V power through a Micro USB port, making it easy to power from a standard USB adapter or power bank during testing and prototyping.\u003c\/p\u003e\n\n\u003ch4\u003eQ: Can the XY-J02 timer module cycle automatically without a trigger signal?\u003c\/h4\u003e\n\u003cp\u003eA: Yes. In mode P3.2, the module begins its ON\/OFF cycle automatically as soon as power is applied — no external trigger is needed. You can set the ON time (OP), OFF time (CL), and the number of cycles (LOP), including infinite cycling.\u003c\/p\u003e\n\n\u003ch4\u003eQ: What is the maximum load the relay on this module can switch?\u003c\/h4\u003e\n\u003cp\u003eA: The onboard relay can switch loads up to DC 30V \/ 5A or AC 220V \/ 5A. The relay output is a passive contact, meaning it does not supply power itself — it controls the connection of an external power circuit to your load.\u003c\/p\u003e\n\n\u003ch4\u003eQ: Will my settings be lost if power is cut to the XY-J02 module?\u003c\/h4\u003e\n\u003cp\u003eA: No. All configured parameters — including the selected operating mode, OP on-time, CL off-time, and LOP cycle count — are stored in non-volatile memory and are automatically restored the next time the module is powered on.\u003c\/p\u003e\n\n\u003ch4\u003eQ: What timing ranges are available on the XY-J02?\u003c\/h4\u003e\n\u003cp\u003eA: The timing is continuously adjustable across three ranges selected by the decimal-point position: 0.1–99.9 seconds (tenths resolution), 1–999 seconds (whole-second resolution), or 1–999 minutes. This gives a full span from 0.1 second up to over 16 hours.\u003c\/p\u003e\n\u003c!-- production-packaging-notice --\u003e\n\u003ch3\u003eProduction \u0026amp; Packaging Notice\u003c\/h3\u003e\n\u003cp\u003eTo maintain high stock availability and fast shipping times, our items are sourced from multiple verified manufacturing facilities. While the core quality, materials, and product specifications remain identical, you may notice slight variations in the packaging design, manufacturing origin, or the wording of the printed instructions.\u003c\/p\u003e\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"What power supply does the XY-J02 relay timer module require?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The XY-J02 relay timer module supports a wide input voltage of 6–30V DC. It also conveniently accepts 5V power through a Micro USB port, making it easy to power from a standard USB adapter or power bank during testing and prototyping.\"}}, {\"@type\": \"Question\", \"name\": \"Can the XY-J02 timer module cycle automatically without a trigger signal?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Yes. In mode P3.2, the module begins its ON\/OFF cycle automatically as soon as power is applied — no external trigger is needed. You can set the ON time (OP), OFF time (CL), and the number of cycles (LOP), including infinite cycling.\"}}, {\"@type\": \"Question\", \"name\": \"What is the maximum load the relay on this module can switch?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The onboard relay can switch loads up to DC 30V \/ 5A or AC 220V \/ 5A. The relay output is a passive contact, meaning it does not supply power itself — it controls the connection of an external power circuit to your load.\"}}, {\"@type\": \"Question\", \"name\": \"Will my settings be lost if power is cut to the XY-J02 module?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"No. All configured parameters — including the selected operating mode, OP on-time, CL off-time, and LOP cycle count — are stored in non-volatile memory and are automatically restored the next time the module is powered on.\"}}, {\"@type\": \"Question\", \"name\": \"What timing ranges are available on the XY-J02?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The timing is continuously adjustable across three ranges selected by the decimal-point position: 0.1–99.9 seconds (tenths resolution), 1–999 seconds (whole-second resolution), or 1–999 minutes. This gives a full span from 0.1 second up to over 16 hours.\"}}]}\u003c\/script\u003e\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\": \"https:\/\/schema.org\", \"@type\": \"BreadcrumbList\", \"itemListElement\": [{\"@type\": \"ListItem\", \"position\": 1, \"name\": \"Home\", \"item\": \"https:\/\/0dwbi8-fa.myshopify.com\/\"}, {\"@type\": \"ListItem\", \"position\": 2, \"name\": \"Home page\", \"item\": \"https:\/\/0dwbi8-fa.myshopify.com\/collections\/frontpage\"}, {\"@type\": \"ListItem\", \"position\": 3, \"name\": \"XY-J02 Time Delay Relay Timer Module 6-30V | 999 Min Cycle\", \"item\": \"https:\/\/0dwbi8-fa.myshopify.com\/products\/xy-j02-time-delay-relay-timer-module-6-30v-999-minute-cycle\"}]}\u003c\/script\u003e","brand":"Quake","offers":[{"title":"Default Title","offer_id":50286586200291,"sku":"\u003cnone\u003e","price":8.51,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0820\/9439\/1523\/files\/Sa2ebf6ebf2094cbeb4bf3c3adeeb4842p.webp?v=1790289899","url":"https:\/\/quakegoods.com\/products\/xy-j02-time-delay-relay-timer-module-6-30v-999-minute-cycle","provider":"Quake","version":"1.0","type":"link"}